Basket type strainer Pressure drop calculation
Basket type strainer Pressure drop calculation : To calculate the pressure drop across a basket type strainer, you will need to know the following information:
-The flow rate of the fluid passing through the strainer (in gallons per minute or cubic meters per second)
-The viscosity of the fluid (in centipoise or Pa·s)
-The size and mesh of the strainer basket (measured in microns or mesh)
-The specific gravity of the fluid
Once you have this information, you can use the following equation to calculate the pressure drop:
ΔP = K x Q² x μ / (C x D² x 𝜌)
Where:
ΔP = pressure drop (in psi or Pa)
K = a constant based on the strainer basket mesh and size
Q = flow rate (in gallons per minute or cubic meters per second)
μ = viscosity of the fluid (in centipoise or Pa·s)
C = a constant based on the strainer basket design
D = the inside diameter of the strainer (in inches or millimeters)
𝜌 = density of the fluid (in pounds per cubic foot or kilograms per cubic meter)
It’s important to note that this is a simplified equation, and the actual pressure drop will depend on a number of factors, including the fluid properties, strainer design, and the specific application.
Basket strainer types : Basket Strainer type Open the top cover , Basket strainer type manual brush handle , Basket Strainer type Duplex , Automatic Basket Strainer type.
Product Group Expert : Basket Strainer , Handle Wheel Washing Basket Strainer , Automatic Basket Strainer , Automatic Backwash Strainer , Duplex Basket Strainer , Automatic Strainer Machine , Automatic Strainer Self-Cleaning , Automatic Self-Cleaning Water Filters, Automatic Backwash Drain Filter, Automatic Backwashing Strainer , Automatic Backflush Strainer , Automatic Water Strainer ,Hydrocyclone Separator Filter , T Strainer Filter , Y Strainer and Temporary filter. strainer filter catalogue